Microbiology
Textbooks
Boundless Microbiology
Microbial Genetics
Bioinformatics
Microbiology Textbooks Boundless Microbiology Microbial Genetics Bioinformatics
Microbiology Textbooks Boundless Microbiology Microbial Genetics
Microbiology Textbooks Boundless Microbiology
Microbiology Textbooks
Microbiology
Concept Version 7
Created by Boundless

DNA Sequencing Based on Sanger Dideoxynucleotides

Sanger sequencing is based on the incorporation and detection of labeled ddNTPs as terminal nucleotides in DNA amplification.

Learning Objective

  • Recall dideoxynucleotide sequencing


Key Points

    • The lack of the second deoxy group on an dNTP making it ddNTP, stops the incorporation of further nucleotides, this termination creates DNA lengths stopped at every nucleotide, this is central to further identifying each nucleotide.
    • Different labels can be used, ddNTPS, dNTPs and primers can all be labelled with radioactivity and fluorescently.
    • Using fluorescent labels, dideoxy sequencing can be automated allowing high-throughput methods which have been utilized to sequence entire genomes.

Terms

  • chromatogram

    The visual output from a chromatograph. Usually a graphical display or histogram.

  • dideoxynucleotide

    Any nucleotide formed from a deoxynucleotide by loss of an a second hydroxy group from the deoxyribose group


Full Text

Sanger sequencing, also known as chain-termination sequencing, refers to a method of DNA sequencing developed by Frederick Sanger in 1977. This method is based on amplification of the DNA fragment to be sequenced by DNA polymerase and incorporation of modified nucleotides - specifically, dideoxynucleotides (ddNTPs).

The classical chain-termination method requires a single-stranded DNA template, a DNA primer, a DNA polymerase, normal deoxynucleotidetriphosphates (dNTPs), and modified nucleotides (dideoxyNTPs) that terminate DNA strand elongation . These chain-terminating nucleotides lack a 3'-OH group required for the formation of a phosphodiester bond between two nucleotides, causing DNA polymerase to cease extension of DNA when a ddNTP is incorporated. The ddNTPs may be radioactively or fluorescently labelled for detection in automated sequencing machines.The DNA sample is divided into four separate sequencing reactions, containing all four of the standard deoxynucleotides (dATP, dGTP, dCTP and dTTP) and the DNA polymerase. To each reaction is added only one of the four dideoxynucleotides (ddATP, ddGTP, ddCTP, or ddTTP). Following rounds of template DNA extension from the bound primer, the resulting DNA fragments are heat denatured and separated by size using gel electrophoresis. This is frequently performed using a denaturing polyacrylamide-urea gel with each of the four reactions run in one of four individual lanes (lanes A, T, G, C). The DNA bands may then be visualized by autoradiography or UV light and the DNA sequence can be directly read off the X-ray film or gel image.

Sanger sequencing

Different types of Sanger sequencing, all of which depend on the sequence being stopped by a terminating dideoxynucleotide (black bars).

Technical variations of chain-termination sequencing include tagging with nucleotides containing radioactive phosphorus for radiolabelling, or using a primer labeled at the 5' end with a fluorescent dye. Dye-primer sequencing facilitates reading in an optical system for faster and more economical analysis and automation. The later development by Leroy Hood and coworkers of fluorescently labeled ddNTPs and primers set the stage for automated, high-throughput DNA sequencing. Chain-termination methods have greatly simplified DNA sequencing. More recently, dye-terminator sequencing has been developed. Dye-terminator sequencing utilizes labelling of the chain terminator ddNTPs, which permits sequencing in a single reaction, rather than four reactions as in the labelled-primer method. In dye-terminator sequencing, each of the four dideoxynucleotide chain terminators is labelled with fluorescent dyes, each of which emit light at different wavelengths .

Chromatograph

This is an example of the output of a Sanger sequencing read using fluorescently labelled dye-terminators. The four DNA bases are represented by different colours which are interpreted by the software to give the DNA sequence above.

Automated DNA-sequencing instruments (DNA sequencers) can sequence up to 384 DNA samples in a single batch (run) in up to 24 runs a day. DNA sequencers carry out capillary electrophoresis for size separation, detection and recording of dye fluorescence, and data output as fluorescent peak trace chromatograms. Automation has lead to the sequencing of entire genomes.

[ edit ]
Edit this content
Prev Concept
Amplifying DNA: The Polymerase Chain Reaction
Metagenomics
Next Concept
Subjects
  • Accounting
  • Algebra
  • Art History
  • Biology
  • Business
  • Calculus
  • Chemistry
  • Communications
  • Economics
  • Finance
  • Management
  • Marketing
  • Microbiology
  • Physics
  • Physiology
  • Political Science
  • Psychology
  • Sociology
  • Statistics
  • U.S. History
  • World History
  • Writing

Except where noted, content and user contributions on this site are licensed under CC BY-SA 4.0 with attribution required.